DYNA 70025 Rotary Actuators
Designed in collaboration with Stanadyne for direct integration as the pump cover of Stanadyne "D" Series fuel injection pumps

DYNA 70025 rotary actuators integrated onto Stanadyne "D" Series fuel injection pump covers eliminate replacement of internal parts or addition of external linkage. New covers are easily installed simply by removing the existing cover and replacing it with the new one. Sealed unit model prevents pollutants in contaminated fuel from entering the actuator.
Used on Stanadyne fuel injection pump models DB / JDB / DC / DB2 / DB4 / DM2 / DM4.
Standard 70025 Actuator Sealed 70025 Actuator
Learn more about DYNA 70025 actuators or where to buy them.
Click on the globe below.

DYNA 70025 Governor System Specifications:
| Nominal Voltage |
12 Vdc |
24 Vdc |
| Nominal Steady State Current |
2.5 A |
1.94 A |
| Nominal Steady State Current at Stall |
5.8 A @ 24 °C (75 °F) |
3.3 A @ 24 °C (75 °F) |
| Maximum Stall Current |
6 A |
2.2 A |
| Input |
2.5 Vrms minimim speed signal |
| Speed Range |
250--9500 Hz |
| Duty Cycle |
Continuous |
| Temperature Range |
-40 °C to 125 °C (-40 °F to 257 °F) |
| Weight |
1 lb. 12 oz. (0.8 kg) |
| Controllers for 70025 Stanadyne Actuator |
| 12 Vdc |
24 Vdc |
CE Marked |
| 8270-1058 |
8270-1074 |
— |
| 8270-1013 |
8270-1014 |
— |
| 8270-1061 |
— |
Yes |
| 8270-1033 |
— |
Yes |
Old Item
|
New Item
|
Product Sheets
|
Tech
Manuals
|
Comments
|
Actuator for Integrated Installation on Stanadyne Pump
|
DYNC-70025-000-0-12
|
DC70025-002-012
|
DYNA 102 DYNA 123 DYNA 131
|
Woodward 36532
DYNA 130
|
Unsealed unit, with O-ring and seal kit
|
DYNC-70025-000-0-24
|
DC70025-002-024
|
Unsealed unit, with O-ring and seal kit
|
DYNC-70025-001-0-12
|
DC70025-003-012
|
Sealed unit, with O-ring and seal kit
|
DYNC-70025-001-0-24
|
DC70025-003-024
|
Sealed unit, with O-ring and seal kit
|
DYNC-70025-001-1-12
|
DC70025-003-112
|
Sealed unit, no O-ring and seal kit
|
DYNC-70025-001-1-24
|
DC70025-003-124
|
Sealed unit, no O-ring and seal kit
|
DYNC-70025-101-0-12
|
DC70025-102-012
|
Special OEM unit with sensor, O-ring and seal kit
|
DYNC-70025-101-1-12
|
DC70025-102-112
|
Special OEM unit with sensor, no O-ring and seal kit
|
DYNC-70025-200-1-12
|
DC70025-201-112
|
Special OEM unit with O-ring and seal kit
|
DYNC-70025-200-1-24
|
DC70025-201-124
|
Special OEM unit with O-ring and seal kit
|
DYNC-70025-200-2-12
|
DC70025-201-212
|
Special OEM unit. Purchase from Perkins
|
DYNC-70025-200-2-24
|
DC70025-201-224
|
Special OEM unit. Purchase from Perkins
|
Panel-Mounted Controllers
|
DYN1-10784-003-0-12
|
8270-1035
|
DYNA 102 DYNA 123 DYNA 131
|
Woodward 36532
DYNA 130
|
2500-5000 Hz input signal
|
DYN1-10784-003-0-24
|
8270-1075
|
DYN1-10784-000-0-12
|
8270-1058
|
DYN1-10784-000-0-24
|
8270-1074
|
| |
|
DYN1-10786-000-0-12
|
Replaced by DPG Series
|
Woodward 36532
DYNA 130
|
5000-9000 Hz input signal
|
DYN1-10786-000-0-24
|
|
DYN1-10786-001-0-12
|
|
DYN1-10786-001-0-24
|
|