DYNA 8000 Series Rotary Actuators
DYNA 8000 / DYNA 8200 / DYNA 8400
Woodward DYNA 8000 Series rotary actuators are components of governor systems that provide engine governing for speed and power control of piston and gas turbine engines or steam and water turbines.
The DYNA hazardous duty actuators are UL listed for Class I, Division 2, Group D, hazardous duty applications often encountered in petroleum or chemical industries.
ACTUATOR
The actuator consists of an electromagnet with an iron armature rolling on the center shaft bearings, and has a return spring that balances the magnetic force of the armature. When DC current flows in the coil, the magnetic force moves the armature in the stator. This linear motion is transformed into rotary motion through a crank arm that forms part of the output shaft.
The all-electric, proportional actuators are compatible with all engines and can be mounted in any position on the engine.
Torque ranges for the 8000 Series actuators are:
- DYNA 8000: 1.4 N•m (1.0 lb-ft) with a 35° travel range
- DYNA 8200: 4.1 N•m (3.0 lb-ft) with a 45° travel range
- DYNA 8400: 7.3 N•m (5.4 lb-ft) with a 45° travel range
CONTROLLER
The electronic controller is the information processing unit of the governor assembly. It contains electronic components which process the input signal from the magnetic pickup that commands the engine to the desired speed/RPM set into the controller. Electronic adjustments are available on the controller for field adjusting the unit as necessary.
Learn more about DYNA 8000 actuators or where to buy them.
Click on the globe below.
• High reliability due to few moving parts
• Spring returns output shaft to minimum position
• Clockwise and counterclockwise rotations available
• Precise repeatability
• Mounts in any position
Operating Voltage
|
12 Vdc or 24 Vdc ± 20%
|
Ambient Operating Temperature
|
-55 to + 125 °C (-65 to + 255 °F)
|
Mechanical Vibration
|
5 to 500 Hz, Curve F, per MIL-STD. 810D, Method 514-2
|
Connection
|
Terminal strip or “MS” connector
|
Sealed Unit
|
Oil, water, and dust tight
|
DYNA Series
|
Work
|
Torque
|
Output
|
Current @ 12 Vdc
|
Current @ 24 Vdc
|
Nominal Response Time for 63% of Stroke
|
Weight
|
Max. Amps at Stall
|
Nominal Steady State Amps
|
Max. Amps at Stall
|
Nominal Steady State Amps
|
8000
|
1.2 J (0.9 ft-lb)
|
1.4 N·m 1.0 lb-ft
|
Rotary 35°
|
12.5 mA
|
3.5 A
|
9.5 mA
|
1.5 A
|
0.030 sec
|
5.0 kg (11.0 lb)
|
8200
|
2.85 J (2.10 ft-lb)
|
4.1 N·m 3.0 lb-ft
|
Rotary 45°
|
14.75 mA
|
4.5 A
|
14.0 mA
|
3.5 A
|
0.138 sec
|
8.4 kg (18.5 lb)
|
8400
|
5.8 J (4.3 ft-lb)
|
7.3 N·m 5.4 lb-ft
|
Rotary 45°
|
N/A
|
N/A
|
13.0 mA
|
2.0 A
|
0.104 sec
|
12.2 kg (27.0 lb)
|
Also see “Actuator Item No. Cross Reference” tab for voltage, rotation, and hazardous duty specifications on specific actuator item numbers.
DYNA 8000 Series
8000 SERIES ACTUATOR ITEM NUMBER
|
FORMER DYNC ITEM NUMBER
|
VOLTAGE
|
OUTPUT SHAFT ROTATION
|
HAZARODUS DUTY
|
CW
|
CCW
|
|
DC11020-000-012
|
DYNC 11020-000-0-12
|
12 Vdc
|
■
|
|
|
DC11020-000-024
|
DYNC 11020-000-0-24
|
24 Vdc
|
■
|
|
|
DC11020-300-012
|
DYNC 11020-300-0-12
|
12 Vdc
|
■
|
|
■
|
DC11020-300-024
|
DYNC 11020-300-0-24
|
24 Vdc
|
■
|
|
■
|
DC11021-000-012
|
DYNC 11021-000-0-12
|
12 Vdc
|
■
|
|
|
DC11021-000-024
|
DYNC 11021-000-0-24
|
24 Vdc
|
■
|
|
|
DC11021-300-012
|
DYNC 11021-300-0-12
|
12 Vdc
|
■
|
|
■
|
DC11021-300-024
|
DYNC 11021-300-0-24
|
24 Vdc
|
■
|
|
■
|
DC11022-000-012
|
DYNC 11022-000-0-12
|
12 Vdc
|
■
|
|
|
DC11022-000-024
|
DYNC 11022-000-0-24
|
24 Vdc
|
■
|
|
|
DC11022-300-024
|
DYNC 11022-300-0-24
|
24 Vdc
|
■
|
|
■
|
DC11023-000-024
|
DYNC 11023-000-0-24
|
24 Vdc
|
■
|
|
|
DC11023-300-024
|
DYNC 11023-300-0-24
|
24 Vdc
|
■
|
|
■
|
DC11023-350-024
|
DYNC 11023-350-0-24
|
24 Vdc
|
|
■
|
|
For more information on DYNA 8000 actuators, please consult Woodward manual 36569.
The following historical documents are also available for reference:
Product sheets F-22030 and F-23441; Manuals F-22171 and F-23721.
DYNA 8200 Series
8200 SERIES ACTUATOR ITEM NUMBER
|
FORMER DYNC ITEM NUMBER
|
VOLTAGE
|
OUTPUT SHAFT ROTATION
|
HAZARDOUS DUTY
|
CW
|
CCW
|
DC12000-000-012
|
DYNC 12000-000-0-12
|
12 Vdc
|
■
|
|
|
DC12000-000-024
|
DYNC 12000-000-0-24
|
24 Vdc
|
■
|
|
|
DC12001-000-012
|
DYNC 12001-000-0-12
|
12 Vdc
|
■
|
|
|
DC12001-000-024
|
DYNC 12001-000-0-24
|
24 Vdc
|
■
|
|
|
DC12002-000-012
|
DYNC 12001-000-0-12
|
12 Vdc
|
■
|
|
|
DC12003-000-024
|
DYNC 12003-000-0-24
|
24 Vdc
|
■
|
|
|
For more information on DYNA 8200 actuators, please consult Woodward manual 36569.
The following historical documents are also available for reference:
Product sheets F-22030 and F-23441; Manuals F-22171 and F-23721.
DYNA 8400 Series
8400 SERIES ACTUATOR ITEM NUMBER
|
FORMER DYNC ITEM NUMBER
|
VOLTAGE
|
OUTPUT SHAFT ROTATION
|
HAZARDOUS DUTY
|
CW
|
CCW
|
DC14800-000-024
|
DYNC 14800-000-0-24
|
24 Vdc
|
■ †
|
■ †
|
|
(†) Through output shaft makes available both CW and CCW output.
For more information on DYNA 8400 actuators, please consult Woodward manual 36569.
The following historical documents are also available for reference:
Product sheets F-23440 and F-23441; Manuals F-22171 and F-23721.
CONTROLLER ITEM NUMBER
|
FORMER DYN1 ITEM NUMBER
|
VOLTAGE
|
FREQUENCY
|
CE MARKED
|
NON-DERIVATIVE POT MODELS
|
8270-1021
|
DYN1-10654-000-0-12
|
12 Vdc
|
2500–5000 Hz
|
|
8270-1004
|
DYN1-10654-000-0-24
|
24 Vdc
|
2500–5000 Hz
|
|
8270-1072
|
DYN1-10654-001-0-24
|
24 Vdc
|
2500–5000 Hz
|
■
|
DERIVATIVE POT MODELS
|
8270-1024
|
DYN1-10684-000-0-12
|
12 Vdc
|
2500–5000 Hz
|
|
8270-1073
|
DYN1-10684-000-0-24
|
24 Vdc
|
2500–5000 Hz
|
|
Controller Item Number
|
Former DYN1 Item Number
|
Comments
|
Panel Mounted Controllers for DYNA 8000/8200/8400 Actuators
|
—
|
DYN1-10652-000-0-12
|
Replaced by DPG Series
|
—
|
DYN1-10652-000-0-24
|
—
|
DYN1-10653-000-0-12
|
8270-1089
|
DYN1-10653-000-0-24
|
8270-1021
|
DYN1-10654-000-0-12
|
8270-1021
|
8270-1004
|
DYN1-10654-000-0-24
|
8270-1004
|
—
|
DYN1-10656-000-0-12
|
Replaced by DPG Series
|
8270-1079
|
DYN1-10656-000-0-24
|
—
|
DYN1-10682-000-0-24
|
—
|
DYN1-10683-000-0-24
|
8270-1024
|
DYN1-10684-000-0-12
|
8270-1024
|
8270-1073
|
DYN1-10684-000-0-24
|
8270-1073
|
—
|
DYN1-10686-000-0-12
|
Replaced by DPG Series
|
—
|
DYN1-10686-000-0-24
|
—
|
DYN1-10652-001-0-12
|
—
|
DYN1-10652-001-0-24
|
—
|
DYN1-10653-001-0-12
|
—
|
DYN1-10653-001-0-24
|
8270-1077
|
DYN1-10654-001-0-12
|
8270-1072
|
DYN1-10654-001-0-24
|
8270-1072
|
—
|
DYN1-10656-001-0-12
|
Replaced by DPG Series
|
—
|
DYN1-10656-001-0-24
|
—
|
DYN1-10682-001-0-24
|
—
|
DYN1-10683-001-0-12
|
—
|
DYN1-10683-001-0-24
|
—
|
DYN1-10684-001-0-12
|
8270-1076
|
DYN1-10684-001-0-24
|
—
|
DYN1-10686-001-0-12
|
—
|
DYN1-10686-001-0-24
|
Smoke-Limit Controllers for DYNA 8000/8200/8400 Actuators
|
—
|
DYN1-10694-001-0-12
|
Replaced by DPG Series
|
8270-1026
|
DYN1-10694-001-0-24
|
—
|
DYN1-10694-002-0-12
|
8270-1089
|
DYN1-10694-002-0-24
|
For more information on DYNA 8x00 Series controllers, the following historical documents are available for reference:
Product sheets F-22030 and F-23441; Manuals F-22171 and F-23721 (panel mounted)
Product sheets F-24693 and DYNA 129; Manuals F-23721 and DYNA 142 (smoke-limit)
Woodward Item No.
|
Product Literature
|
Description
|
DYNK-10206
|
|
General purpose kit for DYNA 8000 governor. No bracket in kit.
|
DYNK-10350
|
Bulletin 244 *
|
Detroit Diesel 6, 8, 12V71 & 6, 8V92 using DYNA 8000 actuator
|
DYNK-10352
|
Bulletin 246 *
|
Detroit Diesel 8V149, 12V149 & 16V149 using DYNA 8400 actuator
|
DYNK-10355
|
|
Detroit Diesel 16V71, 12V92 & 16V92 using DYNA 8200 actuator
|
(*) Documents are not under Woodward engineering control and are provided for historical reference only