APECS DYNA Plus Actuators
Actuation solutions for small engine control
DYNA DYNA
Plus 1 Plus 4

DYNA Plus actuators can be operated with Woodward controllers to provide an engine governor for speed and power control of piston and gas turbine engines or steam and water turbines. The actuators can also be used in remote positioning and load control systems.
Actuators have output work capacities of 1, 4, 6, and 8 ft-Ibs. No special requirements are needed for mounting the DYNA actuator on the engine. It can be located at any convenient position since there are no requirements for a mechanical drive or oil connections. DYNA 6 actuators are available in standard and explosion-proof models. DYNA 8 actuators' through output shaft allows clockwise and counterclockwise shaft rotation.
Standard features of all DYNA actuators include:
- All-electric
- All engine compatibility
- Mounts in any position
- Engine mounted
- High reliability due to few moving parts
- Proportional actuator
- No hydraulic or oil line
- No special maintenance
- Spring returns output shaft to minimum position
- Precise repeatability
DYNA 6 DYNA 8

Learn more about DYNA Plus actuators or where to buy them.
Click on the globe below.

|
PLUS 1
|
PLUS 4
|
PLUS 6
|
PLUS 8
|
Work
|
J
|
1.6
|
5.8
|
8
|
10.8
|
Ft-lb
|
1.2
|
4.3
|
6
|
8.1
|
Torque
|
N-m
|
1.9
|
7.3
|
10
|
11.2
|
lbf
|
1.4
|
5.4
|
7.5
|
8.3
|
Output
|
Rotary
|
45°
|
45°
|
45°
|
45°
|
Current
|
@ 12 Vdc
|
Max. Amps
@ Stall
|
11.0
|
—
|
—
|
—
|
Nom. Steady State Amps
|
2.5
|
—
|
—
|
—
|
@ 24 Vdc
|
Max. Amps
@ Stall
|
13.5
|
13.0
|
25.0
|
30
|
Nom. Steady State Amps
|
2.6
|
4.6
|
3.5
|
5
|
@ 32 Vdc
|
Max. Amps
@ Stall
|
12.5
|
11.5
|
25.0
|
—
|
Nom. Steady State Amps
|
2.0
|
1.8
|
3.5
|
—
|
|
@ 125 Vdc
|
Max. Amps
@ Stall
|
—
|
—
|
—
|
4.5
|
|
Nom. Steady State Amps
|
—
|
—
|
—
|
1.0
|
Nominal Response Time for 63% of Stroke (Seconds)
|
0.045
|
0.104
|
0.082
|
0.102
|
Speed Range
|
250—9500 Hz
|
Input
|
2.5 Vrms minimum speed signal
|
Note: Non-Woodward documents are not under Woodward engineering control and are provided for historical reference only.
Old Item
|
New Item
|
Product Sheet
|
Tech Manual
|
DYNA PLUS 1
|
DYNC-11000-004-0-12
|
DC11000-004-012
|
F-18080 F-18087 F-19427
|
Woodward 36529
F-16789
|
DYNC-11000-004-0-24
|
DC11000-004-024
|
DYNC-11000-304-0-24
|
DC11000-304-024
|
DYNC-11001-004-0-12
|
DC11001-004-012
|
DYNC-11001-004-0-24
|
DC11001-004-024
|
DYNC-11001-004-0-24
|
DC11001-004-024
|
DYNC-11002-004-0-24
|
DC11002-004-024
|
DYNC-11004-004-0-12
|
DC11004-004-012
|
DYNC-11004-004-0-24
|
DC11004-004-024
|
DYNC-11005-004-0-12
|
DC11005-004-012
|
DYNC-11005-004-0-24
|
DC11005-004-024
|
DYNC-11006-004-0-12
|
DC11006-004-012
|
DYNC-11006-004-0-24
|
DC11006-004-024
|
DYNC-11006-304-0-12
|
DC11006-304-012
|
DYNC-11006-304-0-24
|
DC11006-304-024
|
DYNA PLUS 4
|
DYNC-14000-001-0-24
|
DC14000-001-024
|
F-18080 F-18087 F-19427
|
Woodward 36529
F-16789
|
DYNA PLUS 6
|
DYNC-16000-002-0-24
|
DC16000-002-024
|
F-18080 F-18087 F-19427
|
Woodward 36529
F-16789
|
DYNC-16001-002-0-24
|
DC16001-002-024
|
DYNA PLUS 8
|
DYNC-18000-000-0-24
|
DC18000-000-024
|
F-18087 F-19427
|
Woodward 36529
F-18571
|
Note: Non-Woodward documents are not under Woodward engineering control and are provided for historical reference only.
Old Item
|
New Item
|
Description
|
Product Sheet
|
Tech Manual
|
Actuator-Mounted Controllers for use with DYNA +1
|
DYN1-10003-002-0-24
|
|
Replaced by
DPG Series
|
F-18080 F-18087 F-19427
|
Woodward 36529
F-16789
|
DYN1-10004-002-0-12
|
|
Replaced by
DPG Series
|
DYN1-10004-002-0-24
|
8270-1059
|
|
DYN1-10006-002-0-12
|
|
Replaced by
DPG Series
|
DYN1-10006-002-0-24
|
8270-1068
|
|
Panel-Mounted Controllers for use with DYNA +1 +4 +6 +8
|
DYN1-10502-004-0-24
|
|
|
F-18080 F-18087 F-19427
|
Woodward 36529
F-16789
|
DYN1-10503-004-0-24
|
|
Replaced by
DPG Series
|
DYN1-10504-004-0-12
|
8270-1078
|
|
DYN1-10504-004-0-24
|
8270-1060
|
|
DYN1-10506-004-0-12
|
|
Replaced by
DPG Series
|
DYN1-10506-004-0-24
|
8270-1082
|
|
Actuator-Mounted Controllers Tandem Propulsion for use with DYNA +1 +4 +6 +8
|
DYN1-10024-002-0-24
|
8270-1081
|
Replaced by
DPG Series
|
F-18080 F-18087 F-19427
|
Woodward 36529
F-16789
|
DYN1-10025-002-0-24
|
8270-1067
|
Replaced by
DPG Series
|
DYN1-10026-002-0-24
|
8270-1066
|
|
DYN1-10031-002-0-24
|
|
Replaced by
DPG Series
|
DYNA Actuator Hardware
ITEM NO.
|
DESCRIPTION
|
AKKH-175
|
Actuator Controller Kit
|
Rod end bearings #10/32 bore with 10/32 UNF thread
|
DYNC-174
|
Output Lever Assy
|
For use with 0.375" (3/8") rod end bearings. Overall length: 5.18" (131.5 mm). 5 holes for adjustment.
|
DYNC-182
|
Actuator Lever Kit
|
For use with 0.25" (1/4") rod end bearings. Overall Length: 5.0" (127.0 mm). 5 holes for adjustment.
|
DYNC-201
|
Actuator Lever Kit
|
For use with 0.312" (5/16") rod end bearings. Overall length: 5.0" (127.0 mm). 5 holes adjustment.
|
DYNC-208
|
Actuator Lever Kit
|
For use with +1 actuator and Cummins kits
|
DYNC-607
|
Output Lever Assy
|
For use with +1 actuator used on small horsepower engine applications and 0.165" (#10/32) rod end bearings.
|