Woodward

     

    HighPROTEC


    Image
    Device
    MCDTV4
    MCDGV4
    MRM4
    MCA4
    MRMV4
    MRDT4
    MRI4
    MRU4
    MRA4
    + pdf + ANSI + IEC...
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Line
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    HighPROTEC
    Analog Inputs
    -
    -
    -
    -
    -
    -
    -
    Optional
    Optional
    -
    -
    -
    Analog Outputs
    -
    -
    -
    -
    Optional
    -
    Optional
    Optional
    Optional
    -
    -
    -
    Control and detection of switchgears
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Control and supervision of a circuit breaker (remote or local)
    6
    1
    1
    2
    1
    6
    1
    6
    6
    -
    -
    -
    Current transformer inputs
    4
    -
    4
    8
    8
    4
    -
    8
    Yes
    -
    -
    -
    Output relays
    6(+6)
    5
    5
    6(+6)
    6(+6)
    5
    5
    6(+6)
    7
    -
    -
    -
    Voltage transformer inputs
    4
    4
    -
    -
    4
    4
    4
    4
    4
    -
    -
    -
    Watchdog relay
    1
    1
    1
    1
    1
    1
    1
    1
    1
    -
    -
    -
    100% Stator Ground Fault [27TN/59N]
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    Auto reclosing AR [79]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    Current transformer supervision [60FL]
    Yes
    -
    Yes
    Yes
    Yes
    -
    -
    Yes
    Yes
    -
    -
    -
    Differential protection: Generator [87G]
    -
    -
    -
    Yes
    Yes
    -
    -
    Yes
    -
    -
    -
    -
    Differential protection: Transformer [87T]
    -
    -
    -
    Yes
    Yes
    -
    -
    -
    Yes
    -
    -
    -
    Directional time overcurrent protection [67]
    Yes
    -
    -
    -
    -
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Earth fault directional feature [67N]
    Yes
    -
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Earth fault protection [50N/51N]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Exciter current protection [40/76]
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    Fault Ride Through (FRT)
    Yes
    Yes
    -
    -
    -
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Overexcitation [24]
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    Frequency gradient [81]
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Frequency protection [81O/U]
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    IEC 60870-5-103
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    -
    -
    Inrush stabilisation (2nd harmonic)
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Manual
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    Modbus (TCP)
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    -
    -
    Modbus RTU Protocol
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Yes
    -
    -
    -
    Motor protection: incomplete start [48]
    -
    -
    -
    -
    Yes
    -
    Yes
    -
    -
    -
    -
    -
    Motor protection: max. number of starts [66]
    -
    -
    -
    -
    Yes
    -
    Yes
    -
    -
    -
    -
    -
    Motor protection: undercurrent [37]
    -
    -
    -
    -
    Yes
    -
    Yes
    -
    -
    -
    -
    -
    Negative sequence protection [46]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Output relay matrix
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Parameter sets
    4
    4
    4
    4
    4
    4
    4
    4
    4
    -
    -
    -
    Phase balance [47]
    Yes
    Yes
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Power direction [32/37]
    Yes
    -
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Profibus DP
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    -
    -
    Programmable Logic
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Q->&V<
    Yes
    -
    -
    -
    -
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Residual voltage [59N]
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Resistance earthed / solidly earthed [50N/51N]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Synchrocheck [25]
    Yes
    Yes
    -
    -
    -
    Yes
    -
    Yes
    Optional
    -
    -
    -
    Time Synchronization via SNTP
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Inadvertent Energization [50/27]
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    Sensitive EF isolated/compensated [50SN/51SN]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Thermal replica [49]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Time Date
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Time overcurrent protection [50/51]
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Trip- and auxiliary relays [86]
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Trip circuit resp. control circuit supervision [74TC]
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Vector surge / mains decoupling [78]
    Yes
    Yes
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Voltage dependent function
    Yes
    -
    -
    -
    -
    Yes
    -
    Yes
    -
    -
    -
    -
    Voltage protection [27/59]
    Yes
    Yes
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Voltage transformer supervision [60FL]
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    IEC 61850
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    -
    -
    Intertripping
    Yes
    Yes
    -
    -
    -
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Time Synchronization via Modbus
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Time Synchronization via IEC 60870-5-103
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Optional
    -
    -
    -
    Voltage Restraint Overcurrent [51V]
    Yes
    -
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Voltage Restraint Controlled [51C]
    Yes
    -
    -
    -
    Yes
    Yes
    -
    Yes
    Yes
    -
    -
    -
    Demand Management
    Yes
    -
    Yes
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    THD (Todal Harmonic Distortion) Protection
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    RTD Temperature Protection [23]
    -
    -
    -
    Optional
    Optional
    -
    Optional
    Optional
    Optional
    -
    -
    -
    Wide Frequency Range
    -
    -
    -
    -
    Yes
    Yes
    -
    Yes
    -
    -
    -
    -
    Disturbance recorder
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    -
    -
    -
    Event recorder
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Fault recorder (none volatile)
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Motor Start Recorder
    -
    -
    -
    -
    Yes
    -
    Yes
    -
    -
    -
    -
    -
    Trend recorder
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -

     

    All shown details without any guarantees!  We reserve the right of changes without prior notice.