Woodward

     

    High Tech Line


    Image
    Device
    MRG3-IE
    MRT1
    MRG3-IER
    MRG3-IU0
    MRG3-U0
    MRG3-I
    MRG3
    MRN3-3
    IRU1-UO
    IRI1-ER
    MRL1
    MRA1
    MRM3-2IE
    MRQ1
    MRS1
    MRR1
    MRP2-R3IU
    MRP2-3IU
    MRF3
    MRU3-2
    MRU3-1
    MRN3-2
    MRN3-1
    MRI1-IE
    MRI1-IU
    MRI3-ICE
    MRIK3-ICE
    MRIK3-IE
    MRI3-IHE
    MRI3-ITE
    MRI3-SR
    MRI3-IXR
    MRI3-IX
    MRI3-IE
    MRI3-IRXR
    MRI3-IRER
    MRI3-IRE
    + pdf + ANSI + IEC...
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Click = Show Details
    Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    High Tech Line
    Control and supervision of a circuit breaker (remote or local)
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Current transformer inputs
    4
    4
    4
    4
    4
    4
    1
    4
    4
    4
    4
    4
    3
    4
    -
    -
    -
    -
    -
    3
    3
    -
    3
    1
    4
    -
    -
    1
    -
    -
    -
    3
    -
    3
    4
    -
    4
    Output relays
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    4
    3
    4
    4
    2
    4
    1
    2
    4
    4
    4
    4
    4
    4
    -
    4
    Voltage transformer inputs
    3
    3
    3
    -
    -
    3
    3
    -
    -
    -
    -
    -
    3
    -
    3
    3
    3
    3
    1
    3
    3
    -
    -
    3
    -
    -
    -
    -
    3
    3
    3
    3
    4
    4
    4
    -
    3
    Watchdog relay
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    -
    -
    -
    -
    1
    1
    1
    1
    1
    1
    -
    1
    Auto reclosing AR [79]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Differential protection: Restricted earth fault [64REF]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Diode failure
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Directional time overcurrent protection [67]
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Earth fault directional feature [67N]
    -
    Yes
    Yes
    -
    -
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    Earth fault protection [50N/51N]
    Yes
    Yes
    -
    Yes
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    Yes
    -
    Yes
    Exciter current protection [40/76]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Frequency gradient [81]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Frequency protection [81O/U]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Inrush stabilisation (2nd harmonic)
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Modbus RTU Protocol
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Yes
    Yes
    -
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    -
    -
    Optional
    -
    -
    -
    -
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    Optional
    Motor protection: incomplete start [48]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Motor protection: max. number of starts [66]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Motor protection: undercurrent [37]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Negative sequence protection [46]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Output relay matrix
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    Yes
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Parameter sets
    2
    2
    2
    2
    2
    2
    2
    2
    2
    2
    2
    2
    1
    1
    2
    2
    2
    2
    2
    1
    1
    1
    1
    1
    2
    -
    -
    -
    -
    2
    2
    2
    2
    2
    2
    -
    2
    Phase balance [47]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Power direction [32/37]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Profibus DP
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Optional
    Optional
    Optional
    Optional
    Optional
    Optional
    -
    Optional
    Residual voltage [59N]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    -
    -
    -
    Resistance earthed / solidly earthed [50N/51N]
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    Rotor earth fault protection [64N]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    RS485 Open Data Protocol
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Sensitive EF isolated/compensated [50SN/51SN]
    -
    -
    Yes
    -
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Test block
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    Thermal replica [49]
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Time Date
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Time overcurrent protection [50/51]
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    Yes
    -
    Yes
    Yes
    -
    Yes
    Trip- and auxiliary relays [86]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Trip circuit resp. control circuit supervision [74TC]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Vector surge / mains decoupling [78]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Voltage dependent function
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    -
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Voltage protection [27/59]
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Disturbance recorder
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    -
    -
    Yes
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Fault recorder (none volatile)
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    -
    -
    Yes
    -
    -
    -
    -
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    -
    Yes

     

    All shown details without any guarantees!  We reserve the right of changes without prior notice.