The MFR 1 Series is a family of industrial grade protective relays that offer
multiple protective features in a single package.
Using a digital processor to measure true RMS values enables a high degree
of measuring accuracy regardless of harmonics, transients or disturbing pulses.
View MFR 1 series application overview
The MFR 12 model is a complete generator protection unit packaged into one compact
device. Typical applications are generators and switchgear equipment that
require independent protection architecture. Different packages offer additional
functionality.
- Configurable threshold/control set points
- Configurable alarm delays
- Two-line Liquid Crystal display
- Operation and alarm indication
- Display of measured values
- English/German display language
- PC and front panel configurable
- 3 configurable relays
- True RMS current measurement
- Independent time-overcurrent (TOC) protection (ANSI# 50/51)
- Ground fault (calculated) protection (ANSI# 50GS/51GS)
- 8 configurable relays
- True RMS current measurement
- True RMS voltage measurement
- Independent time-overcurrent (TOC) protection (ANSI# 50/51)
- Ground fault (calculated) protection (ANSI# 50GS/51GS)
- Inverse time-overcurrent protection (IEC 255)
- Inverse time-overcurrent protection with voltage restraint (ANSI# 51V)
- 8 configurable relays
- Ground fault protection (ANSI# 64G)
(measured via neutral displacement voltage max. 100 Vac)
- Ground fault protection
(measured via cable-type transformer max. 35 mA)
- Directional ground fault
- 3 configurable relays
- Ground fault protection (ANSI# 50/51GN)
(measured via current transformer 1 A)
Certifications / registrations: UL/cUL, CE, GL
Download Product Specs:
Download Product Manuals:
Download Certificates:
Download LeoPC1 Configuration Files:
Download LeoPC1 Configuration Program
Please refer to the
Woodward Worldwide Directory and contact your
local sales office for questions about pricing and delivery or product support.
Return to top of the page
Note: Information contained herein is intended for and appropriate to
the purposes of this publication. Woodward reserves the right to update or otherwise
revise any portion of this publication at any time. Technical data and detailed
information is available in Woodward product specs. Specific reliance should be given
only to information contained in purchase order(s), other contractual document(s), or
information otherwise expressly represented in writing by Woodward as correct and accurate
for the specific facts, circumstances and applications.
|