8262-1118

5009FT

TMR, 220VAC, ACT, AI/AO, CCT

Woodward’s fault tolereant 5009FT TMR (Triple Modular Redundant) controls industrial steam turbines of all sizes and types in system-critical applications requiring maximum reliability and availability. This 220VAC steam turbine controller includes an actuator driver, additional analog input and output cards, specifically-designed algorithms and logic to start, stop, control, and protect industrial steam turbines or turbo-expanders, driving compressors, generators, or pumps. The model includes the configuration and commissioning software tools for installation.
Product Type
  • Application Notes
  • Brochure
  • Product Specification
  • Software Manual
  • Technical Manual
  • Software
FEATURES & FUNCTIONALITY

Woodward’s 5009FT TMR controls industrial steam turbines of all sizes and types in system-critical applications requiring maximum reliability and availability. This steam turbine controller includes specifically-designed algorithms and logic to start, stop, control, and protect industrial steam turbines or turbo-expanders, driving compressors, generators, or pumps.

Designed for today's plant standardization practices, the 5009FT control system's versatile program can be configured to meet your production needs. 

Control steam turbines including:

  • Single valve
  • Single extraction
  • Single admission
  • Single extraction/admission

The 5009FT control's unique PID structure makes it ideal for petrochemical or power generation applications.

Control steam plant parameters including:

  • Compressor speed
  • Generator frequency
  • Turbine load
  • Turbine inlet pressures
  • Exhaust header pressures
  • Tie-line power
  • Fault-tolerant I/O handling and processing:
  • Latent fault detection on relay outputs
  • Time-stamped alarms and trips
  • Discrete input time-stamp with 1 ms resolution
  • Analog input time-stamp with 5 ms resolution
  • Extensive fault detection and annunciation—including first-out indication
  • Critical speed avoidance (3 speed bands)
  • Auto start sequence (hot & cold starts)
  • Three sensors per critical parameter can be configured
  • Dual speed/load dynamics
  • Zero speed detection with proximity probe down to 0.5 Hz
  • Peak speed indication for overspeed trip
  • Automatic hand valve operation (using first stage pressure)
  • Independent Modbus® * communication links
  • Remote analog setpoints for all PIDs
  • CCT (Configuration & Commissioning Tool)—17” (43 cm) touchscreen engineering workstation for configuration, service, and Turbine operation.
  •  

Functional capabilities:

  • Speed/frequency control
  • Turbine or generator load control/limiting
  • Extraction and/or admission header pressure control
  • Compressor control (optional add-on)
  • 1 or 2 loop
  • Anti-surge protection
  • Performance control
  • Turbine inlet header pressure control/limiting
  • Turbine exhaust header pressure control/limiting
  • Plant import/export power control/limiting
  • Isochronous load sharing between units (with EGCP-3 controls)
  • Any process directly related to unit load
  • Proportional or integrating Servo Position Control with LVDT/RVDT excitation (part number dependent)