Power Management Accessories

Enhancing functionality and supporting specialized requirements, easYgen-3000XTaccessories ensure seamless integration into complex power systems.

Modules

  • Remote Annunciator – easYlite-200: Provides real time visualization and audible alerts, providing information about system status, malfunctions etc., without needing to go to the main control panel.
  • Digital I/O Expansion Module – IKD: 8 discrete inputs, 8 relay outputs FORM C via CAN bus communication
  • Digital Input Expansion Module: 16 discrete inputs, CAN bus communication, very fast CAN ID configuration via dip-switches
  • Digital Output Expansion Module: 16 discrete inputs, CAN bus communication, very fast CAN ID configuration via dip-switches
  • Group Controller: Allows connection between 496 gensets / power generation units and 1200 breakers for complex applications and large power generation fleets connected together

Software Tools

  • Configuration Software Toolkit:
    • Basic Software License: Included free of charge in the Toolkit download, and enables users to configure, monitor & troubleshoot on easYgen, LS5 and LS6 Breaker Controllers, MFR-300 and other controllers
    • Download link
  • Modbus Master Mapper:
    • Modbus / TCP customization to read and/or write data
    • Flashing of the generated customized Modbus / TCP via Toolkit into the controllers easYgen3000XT and LS-6
    • Mappable address points for read/write tasks to exchange information with Power Electronics (eg. PV Inverters), protection relays, kW Transducers
    • Download link
  • Data Telegram Mapper: Simplify your retrofit projects, customize your Modbus TCP protocol
    • Configure the Modbus data protocols
    • Up to 300 addresses
    • Upload file into the easYgen3000XT or LS-6XT (*.map file)
    • Documentation of the created telegram (HTML file)
    • Download link
  • Emulation of Load Dependent Start Stop: Improve fuel efficiency and reliability, Work through what-if scenarios for your genset fleet
    • Monitor that all or several of the power generating assets does not approach maintenance cycle simultaneously
    • Maintain sufficient reserve power on the bus in anticipation of a large consumer and that the reserve power automatically falls back after the large consumer breaker is closed
    • Start and stop the gensets according to max/min loading criteria, the later especially to help burn car-bon deposits on engines cylinder head
    • Switch ON and OFF the genset at every pre-defined run hours to equalize the total run hours
    • Determine the optimum combination of gensets when the fleet consists of mixed size gensets
    • Download Link
  • HMI Language Customization:
    • Add / change HMI display language of the easYgen3000XT or remote panel XT display
    • Use MS Excel to modify your language
    • Flashing into the devices via ToolKit
    • Simulation of the HMI to check the translation on-the-fly
    • Re-use previously translated texts
    • Download Link
  • Interconnect Mapper:
    • Unlock the full potential of your easYgen with Ethernet communication capabilities
    • Seamlessly send and receive data between easYgen devices with InterConnectMapper
    • Create setup files for EG3000XT and related devices to enable communication via UDP messages
    • Define who sends which data at which rate and subscribe to data from other devices
    • Utilize up to 99 analog values and 99 Boolean values for receiving data from other devices
    • Send all AnalogManager and LogicsManager values, as well as defined indices and constants
    • Group Boolean flags into 16-bit values for efficient data transfer
    • Easily upload map files and SCP files via Woodward Toolkit or ftp access
    • Download Link

Gateway Accessories

  • Remote Access Gateway:
    • Allows users to start or stop generators remotely
    • Gather operational data such as energy consumption, operating hours, temperatures, etc. in the cloud and analyze these trends to reduce maintenance costs
    • Receive alarms via email or SMS when the generator reaches certain thresholds
    • Automatically generate email reports
    • Connect the system to your own servers or applications
  • Fiber Optic Converter: Up to 40km communication range extension via Fibre Optic System, create electromagnetic ruggedness
  • Profibus Converter: ESEPRO device – addresses up to 8 easYgen or LS Series controllers, direct mapping of data into process I/O
  • Ethernet Converter: for the old easYgen3000 – non XT, convert CAN to Ethernet.